5.9.6. Replacement of consolidation of an oil case

The flange of an oil case of the engine is condensed with WSE-M4G323-A4 sealant laying. At emergence of a leak of oil it is necessary to replace consolidation.
Perform work on a viewing ditch, a platform or the elevator.
It will be required to you: face heads "on 10", "on 13", M8 hairpins (5 pieces) not less than 20 mm long.
1. Merge oil from the engine (see. "Replacement of oil in the engine and an oil filter").
2. Turn out four bolts of fastening of the transmission to an oil case.
3. Turn out 13 bolts of fastening of an oil case to the block of cylinders of the engine, accurately hook the screw-driver and remove an oil case. Deaf openings in the block of cylinders under the bolts shown by red shooters need to be protected from sealant hit. For this purpose screw five hairpins of M8 in the block of cylinders.
4. Clear the interfaced surfaces of an oil case and the block of cylinders of old sealant.
5. Apply on the interfaced surface of an oil case special sealant laying (FORD WSE-M4G323-A4 or its analog) in the form of the roller with a diameter of 3-4 mm, at the same time the line of putting sealant has to pass from the inside of fixing openings.
6. Not later than in 10 min. after putting sealant install an oil case on the block of cylinders, turn out hairpins and screw, without tightening, bolts of fastening of a case.

Prevention
For ensuring tightness of consolidation two subsequent operations need to be finished not later than in 5 min. after installation of a case.

7. Screw four bolts of fastening of the transmission to an oil case and tighten their moment 47,0 N · m (4,7 kgfs · м).
8. Tighten bolts of fastening of a case in that order in two stages:
The 1st stage — a preliminary inhaling the moment of 10,0 N · m (1,0 kgfs · l);
The 2nd stage — a final inhaling the moment of 20,0 N · m (2,0 kgfs · м).
9. Fill in oil in the engine (see. "Replacement of oil in the engine and an oil filter").

Note
It is possible to fill in oil and to launch the engine not earlier than in one hour after installation of an oil case: this time is necessary for sealant polymerization.